In what form are gate pulses best supplied to an AC regulator with an R–L load?
Correct answer B. A train of pulses
Explanation
With an inductive load, current lags and the conduction instant varies, so a single short pulse may arrive before the thyristor is forward biased; a pulse train keeps triggering until it turns on.
Answer checked How we write and check questions
Discussion