In a three-phase CSI with balanced line output voltages 120° apart, the chopping angles are chosen to eliminate which harmonics?
Correct answer D. All of these
Explanation
Balanced three-phase operation already removes even and triplen harmonics, so the chopping angles are selected to cancel the remaining low-order ones, such as the 5th, 7th and 11th.