Practice mode Chemical Engineering

Which condition must hold for a centrifugal pump to run without cavitation?

Correct answer B. Available NPSH must exceed required NPSH

Explanation

Net positive suction head available is what the system supplies above vapour pressure at the pump inlet; required NPSH is what the pump needs. Keeping available above required prevents vapour bubbles forming and collapsing on the impeller. Reversing the inequality is exactly the condition under which cavitation damage occurs.

Report a problem

Answer checked How we write and check questions

Tip: press A, B, C or D to answer, and N for the next question.